Check Valves – Double Acting Pilot
VRDE – Double Acting Pilot Check Valves
Symbol | Code | Max. Flow (L/min.) | Max. Pressure (bar) | Port Sizes |
---|---|---|---|---|
VRDE140 | 15 | 350 | 1/4" BSPP | |
VRDE380 | 35 | 350 | 3/8" BSPP | |
VRDE120 | 45 | 350 | 1/2" BSPP | |
VRDE340 | 70 | 350 | 3/4" BSPP |
VRDL - Double Acting Pilot Check Valves
Symbol | Code | Max. Flow (L/min.) | Max. Pressure (bar) | Port Sizes |
---|---|---|---|---|
![]() | VRDL140N | 35 | 350 | 1/4" BSPP |
VRDL380N | 35 | 350 | 3/8" BSPP | |
VRDL120N | 60 | 350 | 1/2" BSPP |
VRDF - Double Acting Pilot Check Valves
Symbol | Code | Max. Flow (L/min.) | Max. Pressure (bar) | Port Sizes |
---|---|---|---|---|
VRDF3801132 | 35 | 350 | 3/8" BSPP | |
VRDF3801632 | 35 | 350 | 3/8" BSPP | |
VRDF1201132 | 50 | 350 | 3/8" BSPP | |
VRDF1201632 | 50 | 350 | 3/8" BSPP |
Double check valves are designed to control the flow with the ability to adjust. The valves allow free flow from line 2 (valve) to line 1 (load). The return flow isn’t blocked.
Features of Double acting pilot check valves
Design principles and features:
• Pilot ratio suitable for most applications;
• Small spills in the closed position, less than 1 drop per minute;
• Option: manual emergency opening screw-in case of pilot pressure failure.
2 double check valves are capable of providing a maximum flow of liquid up to 70 liters per minute while maintaining pressure up to 350 bar.
Double acting pilot check valve from Metkoff Ltd.
Metkoff Ltd. have made a large catalog of hydraulic double check valves from well-known manufacturers. If you haven’t found the product you need on the site, call us, send an email or contact us using a special online form. We will send a complete product catalog of our company.